- This video is a demo on how to change a card in a Compactlogix PAC rack.
- Slot numbering for Allen Bradley PLC are fundamentally important to identify where your cards are on the back-panel. Here are picture of PLC that identifies how the slot numbers are allocated.
Hello Experts, I would like to get some explaination on the Rack and Slot selection when selecting node address. What does it mean by the option of which module you want to reach question.Does here module meant on a CPU with a IP address or any IO modu.
Plc Slot Numbering Chart
Plc Slot Numbering Machine
List of TCP port numbers used by commercial equipment controllers:
Plc Slot Numbering System
- Allen Bradley – All newer Rockwell PLC’s : 44818 (See List Below for more details)
- Allen Bradley – Older Rockwell AB PLC5E and SLC5/05 use TCP 2222
- BECKHOFF Embedded PC: 48898
- C-more HMI Programming: 9999
- Danfoss ECL Apex: 5050
- FATEK FB Series: 500
- GE Fanus Series 90-30: 18245
- GE SRTP uses TCP ports 18245 and 18246
- GE QuickPanels use TCP port: 57176
- HITACHI EHV Series: 3004
- KEYENCE KV-5000: 8501
- Korenix 6550: 502
- Koyo Ethernet: 28784
- LS GLOFA FEnet: 2004
- LS XGB FEnet: 2004
- LS XGK FEnet: 2004
- Memobus (Yaskawa MP Series Controllers): 502
- Mitsubishi FX: 1025
- MITSUBISHI FX3u (Ethernet): 5001
- MITSUBISHI MELSEC-Q (Ethernet): 4999
- MITSUBISHI MR-MQ100 (Ethernet): 4999
- MITSUBISHI QJ71E71 (Ethernet): 5002
- MODBUS TCP/IP (Ethernet): 502
- MODBUS Server (Modbus RTU Slave): 502
- Omron PLC: 9600
- Panasonic FP (Ethernet): 9094
- Panasonic FP2 (Ethernet): 8500
- Parker Drives using MODBUS TCP/IP (Ethernet): 502
- Red Lion HMI’s: 789
- SAIA S-BUS (Ethernet): 5050
- Schleicher XCX 300: 20547
- Siemens S7 protocol uses TCP port: 102
- Toshiba Series PLC’s uses Modbus port: 502
- Trio (MODBUS RTU, TCP/IP): 502
- Unitronics Socket1 – TCP slave: 20256
- Unitronics Socket2 – TCP slave: 502
- Unitronicsw Socket3 – TCP slave: 20257
- Wago CODESYS – TCP: 2455
- YAMAHA NETWORK BOARD Ethernet RCX series uses telnet port: 23
- YASKAWA MP Series Ethernet: 10000
- YASKAWA MP2300Siec: 44818
- YASKAWA SMC 3010 (Ethernet): 23
- Yokogawa FA-M3 (Ethernet): 12289
Newer Rockwell Allen Bradley Detailed Equipment List for TCP Port 44818
1756-ENET
1756-ENBT
1756-EWEB
1794-AENT
1734-AENT
1769-L35E, 1769-L32E
1788-ENBT
1761-NET-ENI
1785-LXXE
1785-ENET
1747-L55x
1763-L16x
1766-L32x
PowerMonitor 1000
PowerMonitor 3000
PowerMonitor 5000
PanelView
RSLinx Classic
RSLinx Enterprise
INTERCHANGE (rsicd)
Plc Slot Numbering Software
Older Rockwell Allen Bradley Equipment List TCP Port 2222
1785-Lxxe
1785-ENET
1771-DMC(x)
1747-L55x
5820-EI
PowerMonitor II
INTERCHANGE
PowerMonitor 1000
PowerMonitor 3000
PowerMonitor 5000
RSLinx Classic